Comfortable: 29.4 °C-SETHeat Alert: 31.8 °C-SETEmergency: 32.5 °C-SETDesign Failure: 33.9 °C-SETamihanan.amihanan.amihanan. thermal resilience in rowhouses It was during my third year in architecture school when I first learned about the housing crisis in the Philippines. Aside from the housing backlogs, I’ve also discovered that existing mass housing developments are substandard. As a Filipino architecture student, it is one of the things that I struggled to accept. Hence, I found the imminent need to find as solution. Amihanan is my personal plea for a better quality of life in the country. I was sure that affordable housing does not equate to a whole list of compromises and that affordability does not stop at the construction phase. The term stems from “Amihan”, which is the Tagalog term for the cool northeast monsoon winds. The addition of the suffix “-an” gives it another meaning — “to put cool winds”. This work answers aimed not only to provide housing, but also to ensure that each unit would remain livable despite worsening global warming. Aside from this, it is also designed to create a sense of community and connectivity. I aimed for it to be a home that can be accessible to many Filipinos, if not most. This project involved real-life data and multiple simulations in its pre-design phases. These allowed me to come up with performance-based design solutions that ensures each unit would be able to sustain habitable temperatures, even during long periods of heat waves or power interruptions. My study revealed that intentional planning, enhanced building envelope, alongside with adaptive behaviors can achieve just that. habitable temperatures and survivability. Using thermal comfort surveys, I was able to come up with temperature thresholds that served as performance indicators for thermal resilience in rowhouse developments in Trece Martires, Cavite. Further investigation revealed that conventional building envelopes trap heat, exacerbating users’ thermal stress and user- led modifications are not enough. 1 2 3 4 CONVENTIONAL CONSTRUCTION CHB Masonry Wall, Plastered Finish Pre-painted Roofing Sheets on Steel Framing Plain Cement on Metal Decking for 2F Slab OCCUPANT-LED MODIFICATIONS 1.Provision of canopy or shading 2.Rear extensions (partial or full) 3.Interior wall partitions 4.Ceiling insulations

construction assemblies. Findings show that low-thermal mass assemblies with ventilated air gaps can reduce 1.37°C-SET on average and lower threshold exceedances during the summer by 3.73°C-days SET. External Wall Assembly 0.5mm thk. Aluminum Metal Cladding 35mm Ventilated Air Gaps for Passive Cooling 50mm thk. Rockwool Insulation 9mm thk. Fiber Cement Board Interior Wall Assemblies 6mm thk. Fire-rated Calcium Silicate Boards (in fulfillment of the Fire Code) 25mm thk. Rockwool Insulation (for masking sound and rejecting heat) 35mm thk. Ventilated Air Gaps for Passive Cooling the z-block. Given that changing construction assemblies provided marginal changes, the next thing to consider was the unit massing. The Z- block was devised in order to maximize natural ventilation potential. I thought of this after my observation that corner units have slightly cooler indoor temperatures.